FM Transmitter Measurement Report
Created: 2023-11-02 19-55-47
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
91.70 MHz |
5/5, 44 dBuV |
|
Pilot |
RDS |
Phase
Difference |
7.1 kHz |
0.0 kHz |
No phase relation found. |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
0,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 75,0
kHz |
9 kHz |
26 kHz |
18973 |
0,0000 |
|
Modulation Power
Limit |
Measuring
Tolerance |
9,0 dBr |
1,0 dBr |
MIN |
AVE |
MAX |
% above
10,0 dBr |
-4,2 dBr |
-2,09 dBr |
-0,1 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
" " |
0000 |
0 (No PTY) |
0 |
0 |
0 |
0 |
--:-- |
RT |
- |
AF |
EON |
|
- |
|
|